meta data for this page
Differences
This shows you the differences between two versions of the page.
| Next revision | Previous revision | ||
| enterprise:hitachi:solutions:run_mpc_on_svp [2021/02/01 20:00] – external edit 127.0.0.1 | enterprise:hitachi:solutions:run_mpc_on_svp [2021/02/02 18:30] (current) – mchus | ||
|---|---|---|---|
| Line 1: | Line 1: | ||
| + | ====== How to Launch MPC Panel on a Gx00 SVP ====== | ||
| + | ===== Symptom ===== | ||
| + | |||
| + | * MPC is not available and System Option Mode needs to be changed | ||
| + | |||
| + | ===== Environment ===== | ||
| + | |||
| + | * Hitachi Virtual Storage Platform Gx00 (VSP Gx00), HM800 | ||
| + | |||
| + | ===== Resolution ===== | ||
| + | |||
| + | **Note:** These are not supported options. | ||
| + | |||
| + | ==== Method 1 ==== | ||
| + | |||
| + | - Create an empty text file named MPC.INI in the C: | ||
| + | - Reboot the SVP and Login back in as SVP. | ||
| + | - Once you have finished your MPC operations - delete the C: | ||
| + | |||
| + | ==== Method 2 ==== | ||
| + | |||
| + | Launch **zSv_Svp_main** from **C: | ||
| + | |||
| + | ===== Additional Notes ===== | ||
| + | |||
| + | Please note that running the SVP in MPC mode is not supported and should not be used. | ||
| + | |||
| + | {{tag> | ||